Volume 6, Issue 2 (Summer 2014 2014)                   2014, 6(2): 371-379 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ghafouri Safa S, Mirzaali A, Ghorbanpour R, Kamali H, Gholizadeh A. Performance evaluation of wastewater treatment facilities in selected hospitals of North Khorasan in 2012-2013. North Khorasan University of Medical Sciences 2014; 6 (2) :371-379
URL: http://journal.nkums.ac.ir/article-1-351-en.html
Abstract:   (5019 Views)

Abstract Background & Objectives Hospital wastewater due to containing many hazardous agents such as infective elements, pharmacy substances, chemical and radioactive agents has a special sensibility. So it is necessary to transfer, treatment and disposal the wastewater of medical centers. This survey aimed to determine wastewater pollution rate in order to achive an accurate planning requirement in bojnurd Materials & Methods in this cross-sectional study, wastewater quality of 3 hospitals was evaluated over a period of 5 months in the North khorasan Medical Sciences University in Bojnurd in 91-92. None of these hospitals had treatment plant. Samples were transferred to the chemistry lab. Then, BOD5, COD, TSS, pH, temperature and concentration of Amoxicillin were measured in the lab in 190 nm wavelenth. Results The results showed that, the higher average BOD5 and COD in Bentolhoda hospital wastewater over the other two, but the concentration of TSS in Imam Reza Hospital was highest.These findings could be justified on the grounds of the usage of Bentolhoda hospital (maternity). The avearges of pH of the studied hospitals were slightly alkaline which was suitable for biological processes. Amoxicilline concentration of hospitals Imam Ali, Imam Reza and Bentolhoda were 64.88 and 259.4 and 56.49 respectively Conclusion Our results showed all of these parameters are higher than its standard level. So it is necessary to have control on hospital wastewater treatment to prevent entrance of hazardous materials to municipal. Therefore, more researches and making positive attitude in related responsible to refine wastewater of these hospitals are suggested.

Full-Text [PDF 1417 kb]   (4495 Downloads)    
Type of Study: Orginal Research | Subject: Basic Sciences
Received: 2015/03/16 | Accepted: 2015/03/16 | Published: 2015/03/16

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of North Khorasan University of Medical Sciences

Designed & Developed by: Yektaweb