<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>North Khorasan University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی خراسان شمالی</title_fa>
<short_title>Journal of North Khorasan University of Medical Sciences</short_title>
<subject></subject>
<web_url>http://journal.nkums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8701</journal_id_issn>
<journal_id_issn_online>2008-8698</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/nkums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2011</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی دقت فشار سنجهای بیمارستانهای شهرستان سبزوار </title_fa>
	<title>Study of the accuracy of sphygmomanometers in hospitals in Sabzevar</title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Orginal Research</content_type>
	<abstract_fa>&lt;p&gt;چکیده زمینه و هدف: فشار سنجها زیربنای اندازه گیری فشار خون هستند و مشخص گردیده که این ابزار بویژه در مواردی که در اماکن عمومی و به وفور استفاده می&#8204;شوند ممکن است دقیق نباشند و در اندازه گیری دقیق فشار خون سبب خطا گردند. در این مطالعه ما تمامی فشارسنجهای در حال استفاده در بیمارستانهای شهر سبزوار را از نظر دقت و شرایط فیزیکی بررسی کردیم. مواد و روش کار: در این مطالعه توصیفی- مقطعی کلیه فشارسنجهای بیمارستانهای سبزوار مورد بررسی قرار گرفتند.63 فشار سنج با یک فشارسنج جیوه&#8204;ای استاندارد مقایسه شدند. انحراف عقربه فشار سنج آنروئید و سطح جیوه انواع جیوه&#8204;ای از صفر در حالت استراحت بررسی شد. میزان افت فشار از 300 میلیمتر جیوه پس از یک دقیقه بررسی شد و از نرم افزارSPSS 11.5 و آمار توصیفی برای توصیف یافته&#8204;ها استفاده گردید. یافته ها: 50 فشارسنج (4/79%) در حالت استراحت بر روی صفر قرار نداشتند. 9/88% فشار سنجها پس از بسته شدن به دور یک قوطی استوانه&#8204;ای با قطر حدود 32 سانتیمتر و پر هوا شدن تا 300 میلیمتر جیوه، پس از یک دقیقه افت فشار بیشتر از 15 میلیمتر جیوه داشتند. میانگین تفاوت فشارسنجها با فشارسنج استاندارد و در سطح 100 میلیمتر، 67/6 میلیمتر جیوه بود. 54% فشارسنجها در مقایسه با فشارسنج استاندارد تفاوت فشار بیشتر از 4 میلیمتر جیوه داشتند. نتیجه گیری: اکثر فشار سنجهای در حال استفاده دقیق نبودند و باید کالیبره شده و یا از رده خارج شوند. لازم است که یک مرکز جهت کالیبراسیون منظم و دوره&#8204;ای فشار سنجها در بیمارستانها مستقر گردد&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;Abstract Background and Objective: Sphygmomanometers are instruments nessesery for the basis of blood pressure measurement, it is well established that this device especially when is used in general practice may often be inaccurate and may cause errors in the measurement of accurate blood pressure. In this study we carried out an analysis of all aneroid and mercury sphygmomanometers currently in use in Sabzevar hospitals for their accuracy and physical condition. Materials and Methods: In this descriptive cross sectional study, all sphygmomanometers currently in use in Sabzevar hospitals were tested. A total 63 sphygmomanometers were compared with a standard mercury sphygmomanometer. Deviation of the hand of the aneroid sphygmomanometers and the mercury level of the mercury sphygmomanometers at rest were studied. The drop in pressure from 300mmHg was studied after one minute. SPSS 11.5 software and descriptive statistics were used to describe the data. Results: 50 (79.4%) out of 63 sphygmomanometers were not level of reference zero at rest. 88.9% of the sphygmomanometers had a pressure loss of more than 15 mmHg in one minute, when the cuff was inflated to 300mmHg around a can &amp;ndash; with a circumference of about 32 cm. the mean of difference between the sphygmomanometers and the standard sphygmomanometer in the 100 mm level was 6.67 mmHg. 54% of the sphygmomanometers showed a difference of more than 4 mmHg with the standard sphygmomanometer. Conclusion: Most in use sphygmomanometers were not accurate and must either be calibrated or must be out of use. We recommend that all hospitals need to have procedures in place for the regular calibration of their sphygmomanometers.&lt;/p&gt;
</abstract>
	<keyword_fa>واژه های کلیدی: اندازه گیری, دقت, فشار سنج, کالیبراسیون </keyword_fa>
	<keyword>Key words: Accuracy, Calibration, Measurement, Sphygmomanometers </keyword>
	<start_page>57</start_page>
	<end_page>62</end_page>
	<web_url>http://journal.nkums.ac.ir/browse.php?a_code=A-10-25-219&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Khalili</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خلیلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846008300</code>
	<orcid>10031947532846008300</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی سبزوار</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Rad </last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>راد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846008301</code>
	<orcid>10031947532846008301</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی سبزوار</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
