<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>North Khorasan University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی خراسان شمالی</title_fa>
<short_title>nkums</short_title>
<subject></subject>
<web_url>http://journal.nkums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8701</journal_id_issn>
<journal_id_issn_online>2008-8698</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/nkums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی صحت محاسبات دوز سیستم طراحی درمان ایزوگری در میدانهای متقارن و نامتقارن دستگاه شتاب دهنده خطی الکتا کامپکت در فانتوم آب</title_fa>
	<title>Accuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator</title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Orginal Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:nasimYW;&quot;&gt;&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;مقدمه: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;پرتودرمانی یکی از مهمترین روشهای درمان سرطان می&#8204;باشد. در پرتودرمانی از میدان های متقارن و نامتقارن بهره گرفته می&#8204;شود که توزیع دوز پرتویی در آنها متفاوت است. برای محاسبه توزیع دوز، از سیستم&#8204;های طراحی درمان کامپیوتری استفاده می&#8204;شود که باید صحت محاسبات قابل قبولی داشته باشند. هدف از این مطالعه، بررسی صحت دوز محاسبه شده توسط سیستم طراحی درمان ایزوگری در میدان&#8204;های متقارن و نامتقارن در فانتوم آب با استفاده از دوزیمتر اتاقک یونش می&#8204;باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;روش کار:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt; اندازه گیری عملی توسط دوزیمتر اتاقک یونش &lt;/span&gt;Semiflex در فانتوم آب PTW-MP3 انجام گرفت. داده های درصد دوز عمقی روی محور مرکزی باریکه و پروفایل دوز در عمق 10 سانتیمتر، برای میدان های مربعی با ابعاد 5&amp;times;5، 10&amp;times;10، 15&amp;times;15، 20&amp;times;20 و 30&amp;times;30 سانتیمتر و میدان های مستطیلی 8&amp;times;20 و 10&amp;times;15 سانتیمتر و میدان های half beam به ابعاد 6&amp;times;10 و 7&amp;times;15 سانتیمتر اندازه گیری شد. داده های متناظر از سیستم طراحی درمان استخراج گردید و توسط شاخص گاما با یکدیگر مقایسه شدند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt; داده های دوزیمتری و سیستم طراحی درمان، برای درصد دوز عمقی و پروفایل دوز در توافق خوبی بودند و تقریبا برای تمامی نقاط، مقدار شاخص گاما با معیارهای سخت گیرانه 2% اختلاف دوز و &lt;/span&gt;mm&lt;sup&gt;2&lt;/sup&gt; اختلاف فاصله، کمتر از یک بود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;نتیجه گیری:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt; نتایج، دقت قابل قبول سیستم طراحی درمان ایزوگری در محاسبات دوز، برای میدان های باز متقارن و نامتقارن در فانتوم همگن آب، را نشان می دهد&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Arial;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;b&gt;Introduction:&lt;/b&gt; Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose calculated by the Isogray treatment planning system in symmetric and asymmetric fields in the water phantom using ionization chamber dosimeter.&lt;br&gt;
&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;line-height:107%&quot;&gt;Methods:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;line-height:107%&quot;&gt; Practical measurements were performed by a Semiflex ionization chamber dosimeter in the PTW-MP3 water phantom. Depth dose data on the central axis of the beam and dose profile at a depth of 10 cm, for square fields with dimensions of 5 &amp;times; 5, 10 &amp;times; 10, 15 &amp;times; 15, 20 &amp;times; 20 and 30 &amp;times; 30 cm and rectangular fields 20 &amp;times; 8 And 15 &amp;times; 10 cm and half beam fields with dimensions of 6 &amp;times; 10 and 7 &amp;times; 15 cm were measured. Corresponding data were extracted from the treatment planning system and compared with each other by gamma index.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;line-height:107%&quot;&gt;Results:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;line-height:107%&quot;&gt; Dosimetric data and treatment planning system were in good agreement for depth dose percentage and dose profile, and for almost all points, the gamma index value was less than one with strict criteria of 2% dose difference and 2 mm difference in distance.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span style=&quot;line-height:107%&quot;&gt;Conclusions:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;line-height:107%&quot;&gt; The results show the acceptable accuracy of Isogray treatment planning system in dose calculations for symmetric and asymmetric open fields in homogeneous water phantoms&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>پرتودرمانی, دوزیمتری, میدان های متقارن و نامتقارن, سیستم طراحی درمان</keyword_fa>
	<keyword>Radiation Therapy, Dosimetry, Symmetric and Asymmetric Fields, Treatment Planning System</keyword>
	<start_page>15</start_page>
	<end_page>22</end_page>
	<web_url>http://journal.nkums.ac.ir/browse.php?a_code=A-10-1-97&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mahsa </first_name>
	<middle_name></middle_name>
	<last_name>Naghiloo</last_name>
	<suffix></suffix>
	<first_name_fa>مهسا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نقی لو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460021707</code>
	<orcid>100319475328460021707</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Student of medicine, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>دانشجوی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohsen </first_name>
	<middle_name></middle_name>
	<last_name>Khosroabadi</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خسرو آبادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460021708</code>
	<orcid>100319475328460021708</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics and Radiology, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>مربی، گروه فیزیک پزشکی و پرتوشناسی، دانشکده پزشکی، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza </first_name>
	<middle_name></middle_name>
	<last_name>Abaspour</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عباسپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460021709</code>
	<orcid>100319475328460021709</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Pathobiology and Medical Laboratory Science, School of Medicine, North Khorasan University of Medical Science, Bojnurd, Iran</affiliation>
	<affiliation_fa>استادیار، گروه پاتوبیولوژی و علوم آزمایشگاهی، دانشکده پزشکی، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza </first_name>
	<middle_name></middle_name>
	<last_name>Sadeghi</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صادقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460021710</code>
	<orcid>100319475328460021710</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, School of Paramedical Sciences, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran</affiliation>
	<affiliation_fa>استادیار، گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تربت حیدریه، تربت حیدریه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid-Reza </first_name>
	<middle_name></middle_name>
	<last_name>Sadoughi</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صدوقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sadoughi.hamid@gmail.com</email>
	<code>100319475328460021711</code>
	<orcid>100319475328460021711</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Medical Physics and Radiology, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>استادیار، گروه فیزیک پزشکی و پرتوشناسی، دانشکده پزشکی، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
