<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>North Khorasan University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی خراسان شمالی</title_fa>
<short_title>nkums</short_title>
<subject></subject>
<web_url>http://journal.nkums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8701</journal_id_issn>
<journal_id_issn_online>2008-8698</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/nkums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>17</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>other</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی میزان دوز دریافتی پرسنل اتاق عمل‌های ارتوپدی و ستون فقرات حین استفاده از دستگاه C-arm با استفاده از روش‌های تجربی و شبیه‌سازی مونت کارلو</title_fa>
	<title>Assessment of Radiation Dose Received by Orthopedic and Spine Operating Room Personnel during C-Arm Use Using Experimental Methods and Monte Carlo Simulation</title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Orginal Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:nasimYW;&quot;&gt;&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;مقدمه:&lt;/span&gt;&lt;/b&gt; &lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;با گسترش استفاده از &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;C-arm&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; در جراحی&#8204;ها، کارکنان بیشتر در معرض خطر اشعه هستند. &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;ارزیابی دقیق میزان دوز دریافتی در جراحی&#8204;های مختلف یکی از اقدامات مهم برای پیشگیری از عوارض پرتوها است. این مطالعه با هدف ارزیابی میزان دوز دریافتی پرسنل اتاق عمل&#8204;های ارتوپدی و ستون فقرات حین استفاده از دستگاه &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;C-arm&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;، با بهره&#8204;گیری از روش&#8204;های تجربی و شبیه&#8204;&#8204;سازی مونت کارلو انجام شد. &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;روش کار:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt; این &lt;span style=&quot;color:black&quot;&gt;مطالعه، مطالعه&#8204;ای مقطعی است که از مهر تا اسفند 1402 انجام شد. برای ثبت دوز جذبی از دوزیمتر &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;TLD 100&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; و به جای انسان از مولاژ استفاده شد. دوزیمتر روی تیروئید مولاژ قرار گرفت. مولاژها، هم در پشت و هم در جلوی دیوار سربی در سه سمت راست، وسط و چپ قرار گرفتند و دستگاه &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;X-NONE&quot;&gt;C-arm&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; برای شبیه&#8204;سازی جراحی&#8204;های ارتوپدی و نوروسرجری در دو وضعیت قدامی-خلفی و لترال قرار گرفت.&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; تحلیل داده&#8204;ها با استفاده از اس&#8204;پی&#8204;اس&#8204;اس 24 انجام شد. سطح معناداری آزمون&#8204;ها 05/0 در نظر گرفته شد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/b&gt; &lt;a name=&quot;_Hlk136609249&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;به&#8204;&#8204;طورکلی، دوز جذبی مولاژها در وضعیت پشت دیوار سربی به&#8204;طور معناداری کمتر از وضعیت جلوی دیوار بود&lt;/span&gt;&lt;/span&gt;&lt;/a&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; (&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;P&lt;0/05&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;).&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; هنگامی که مولاژ جلوی دیوار باشد، دوز بیشتری در حالت لترال &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;C-arm&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot; style=&quot;color:black&quot;&gt;نسبت به قدامی-خلفی دریافت می&#8204;کند&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;P&lt;0/05&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;)&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;. همچنین، هنگامی که مولاژ پشت دیوار سربی در سمت وسط و چپ باشد، دوز بیشتری در حالت قدامی-خلفی &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;C-arm&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;نسبت به لترال دریافت می&#8204;کند (&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;P&lt;0/05&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;نتیجه&#8204;گیری: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;نتایج این مطالعه نشان&#8204;دهنده تأثیر چشمگیر موقعیت دستگاه &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;C-arm&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black&quot;&gt; و همچنین &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;استفاده از تجهیزات محافظتی &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;بر میزان دوز دریافتی پرسنل اتاق عمل در جراحی&#8204;های ارتوپدی و نوروسرجری است و &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بر اهمیت استفاده از محافظ&#8204;های&lt;span style=&quot;color:black&quot;&gt; مناسب هنگام کار با &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;C-arm&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;تأکید &lt;span style=&quot;color:black&quot;&gt;دارد. &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Arial;&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Introduction:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;Due to&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; increasing use of C-arm in surgeries, personnel are exposed to a greater risk of radiation. Accurate assessment of the dose received during various surgeries is one of the most important measures to prevent radiation-related complications. This study aimed to evaluate the dose received by operating room staff in orthopedic and spinal surgeries while using the C-arm device utilizing experimental methods and Monte Carlo simulation.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Optima&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Method:&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;Th&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;is &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;cross-sectional study &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;was &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;conducted from September to February 2023. To record the absorbed dose, TLD 100 dosimeters were used, and instead of humans, phantoms were utilized. The dosimeter was placed on the thyroid of the phantom. The phantoms were positioned both behind and in front of a lead wall at three locations: right, center, and left. The C-arm device was used to simulate orthopedic and neurosurgery procedures in both anteroposterior and lateral positions. Data analysis was performed using SPSS &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;software (&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;version 24&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;)&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;, with a significance level set at 0.05 for the tests.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Results:&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;The absorbed dose for the phantoms positioned behind the lead wall was significantly lower than that in front of the wall (P&lt;0.05). When the phantom was in front of the wall, it received a higher dose in the lateral position of the C-arm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;, compared to the anteroposterior position (P&lt;0.05). Additionally, when the phantom was placed behind the lead wall in the center and left positions, it received a higher dose in the anteroposterior position of the C-arm,&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; compared to the lateral position (P&lt;0.05).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:107%&quot;&gt;&lt;b&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Conclusion:&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;The results of this study indicate&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;d&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; a significant impact of the C-arm device&amp;#39;s position&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;,&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; as well as the use of protective equipment on the dose received by operating room personnel during orthopedic and neurosurgical procedures. It emphasizes the importance of using appropriate shields when working with the&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt; &lt;/b&gt;&lt;span lang=&quot;X-NONE&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;C-arm.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa>تشعشع, ارتوپدی, نوروسرجری, فلوروسکوپی, روش مونت کارلو</keyword_fa>
	<keyword>Fluoroscopy, Monte Carlo Method, Orthopedics, Neurosurgery, Radiation</keyword>
	<start_page>75</start_page>
	<end_page>82</end_page>
	<web_url>http://journal.nkums.ac.ir/browse.php?a_code=A-10-25-937&amp;slc_lang=other&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammadreza</first_name>
	<middle_name></middle_name>
	<last_name> Zamani</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460029509</code>
	<orcid>0009-0006-3319-4376</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student of Operating Room, Student Research Committee, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد اتاق عمل، کمیته تحقیقات دانشجویی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name> Khosravi</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خسروی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hkhosravi55@gmail.com</email>
	<code>100319475328460029510</code>
	<orcid>100319475328460029510</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associate Professor, Department of Radiology, Faculty of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Behzad</first_name>
	<middle_name></middle_name>
	<last_name> Imani</last_name>
	<suffix></suffix>
	<first_name_fa>بهزاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ایمنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460029511</code>
	<orcid>100319475328460029511</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Operating Room, Faculty of Paramedicine, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه اتاق عمل، دانشکده پیراپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Roya </first_name>
	<middle_name></middle_name>
	<last_name>Najafi Vosoogh</last_name>
	<suffix></suffix>
	<first_name_fa>رویا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نجفی وثوق</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460029512</code>
	<orcid>100319475328460029512</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Health Sciences Research Center, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>استادیار، مرکز تحقیقات علوم بهداشتی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name> Abdi</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عبدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460029513</code>
	<orcid>100319475328460029513</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student of Operating Room, Student Research Committee, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد اتاق عمل، کمیته تحقیقات دانشجویی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
