<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>North Khorasan University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی خراسان شمالی</title_fa>
<short_title>Journal of North Khorasan University of Medical Sciences</short_title>
<subject></subject>
<web_url>http://journal.nkums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8701</journal_id_issn>
<journal_id_issn_online>2008-8698</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034/nkums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>عملکرد دستگاه اسمز معکوس در تصفیه آب مراکز دیالیز بیمارستان امام علی (ع)</title_fa>
	<title>Reverse Osmosis System of water treatment system for dialysis centers in Imam Ali </title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Orginal Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; &lt;em&gt;هر بیمار دارای نارسایی کلیوی در هر مرحله دیالیز با حجم زیادی آب روبرو است که مستقیماً با خون بیمار در تماس است. از این رو آب مورد استفاده در تهیه مایع دیالیز را باید قبل از استفاده با روش&#8204;های اختصاصی تصفیه نمود. هدف این مطالعه تعیین کارایی سیستم&#8204;های اسمز معکوس در بهبود کیفیت آب مورد استفاده در تهیه مایع دیالیز است.&lt;/em&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مواد و روش کار:&lt;/strong&gt; &lt;em&gt;پژوهش حاضر مطالعه مقطعی &lt;/em&gt;&lt;em&gt;&amp;ndash;&lt;/em&gt;&lt;em&gt; توصیفی که به&#8204;&lt;/em&gt; &lt;em&gt;منظور بررسی عملکرد دستگاه اسمز معکوس در تصفیه آب مراکز دیالیز بیمارستان امام علی (ع) و در سه ماهه اول 94 &lt;/em&gt;&lt;em&gt;بر روی 36&lt;/em&gt; &lt;em&gt;نمونه شامل آب خروجی از دستگاه اسمز معکوس و آب شهری &lt;/em&gt;&lt;em&gt;انجام شد&lt;/em&gt;&lt;em&gt;.&lt;/em&gt;&lt;em&gt; نمونه بعد از برداشت و انتقال به آزمایشگاه با استفاده از آخرین روش ارائه شده در کتاب استاندارد متد اندازه&#8204;گیری گردیده و داده ها با استفاده از نرم افزار &lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;17&lt;/span&gt;&lt;/em&gt; &lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt;&lt;/em&gt; &lt;em&gt;مورد آنالیز قرار گرفتند&lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;/em&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; &lt;em&gt;سیستم اسمزمعکوس به طور معنی داری میزان سولفات، نیترات، فلوئور، سختی،&lt;/em&gt; &lt;em&gt;سدیم&lt;/em&gt; &lt;em&gt;و پتاسیم&lt;/em&gt; &lt;em&gt;آب خروجی از اسمزمعکوس را کاهش می&#8204;دهد و میانگین تمامی ترکیبات اندازه&#8204;گیری شده در آب خروجی از اسمزمعکوس &lt;/em&gt;&lt;em&gt;کمتر از استاندارد &lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;AAMI&lt;/span&gt;&lt;/em&gt;&lt;em&gt; و &lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;EPH&lt;/span&gt;&lt;/em&gt;&lt;em&gt; بود&lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;/em&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری:&lt;/strong&gt; &lt;em&gt;سیستم اسمز معکوس می&#8204;تواند کیفیت آب مورد استفاده برای همودیالیز را بهبود دهد&lt;/em&gt; &lt;em&gt;و میانگین تمامی &lt;/em&gt;&lt;em&gt;پارامترهای&lt;/em&gt; &lt;em&gt;اندازه&#8204;گیری شده کمتر از حد استاندارد بوده که نشان&#8204;دهنده این&lt;/em&gt; &lt;em&gt;است که&lt;/em&gt;&lt;em&gt; راندمان دستگاه اسمز معکوس در حذف پارامترهای&lt;/em&gt;&lt;em&gt; اندازه&#8204;گیری شده در حد مطلوب قرار داشته است.&lt;/em&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;واژه&#8204;های کلیدی:&lt;/strong&gt; &lt;em&gt;اسمز معکوس، همودیالیز، تصفیه&lt;/em&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background &amp; Objectives:&lt;/strong&gt; &lt;em&gt;Kidney patients in each dialysis cycle are exposed to extremely large volume of water, which is in direct contact with the patient&amp;rsquo;s blood &lt;span dir=&quot;RTL&quot;&gt;. &lt;/span&gt;Therefore, water used for this purpose should be treated with advanced methods before use for dialysis. The objective of this study was to assess the efficiency of reverse osmosis systems to improve water quality used for dialysis fluid.&lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Material &amp; Methods:&lt;/strong&gt; &lt;em&gt;This is a descriptive-analytic study to Evaluation of Reverse Osmosis System of water treatment system for dialysis centers in Imam Ali&amp;nbsp; Bojnurd ciry during 201&lt;span dir=&quot;RTL&quot;&gt;5&lt;/span&gt;on 36 samples of water from the municipal water was reverse osmosis. Post-harvest and transport of samples to the laboratory using the latest according to the standard methods for water and wastewater examination.&lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results: &lt;/strong&gt;&lt;em&gt;The results of this study showed that the reverse osmosis systems significantly reduce the&lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;em&gt;amount of&lt;/em&gt;&lt;em&gt; sulfate&lt;/em&gt;&lt;em&gt;, &lt;/em&gt;&lt;em&gt;nitrate&lt;/em&gt;&lt;em&gt;, &lt;/em&gt;&lt;em&gt;fluoride&lt;/em&gt;&lt;em&gt;, hardness, &lt;/em&gt;&lt;em&gt;sodium&lt;/em&gt;&lt;em&gt;, &lt;/em&gt;&lt;em&gt;potassium&lt;/em&gt;&lt;em&gt;&lt;span dir=&quot;RTL&quot;&gt;.&amp;nbsp; &lt;/span&gt;&lt;/em&gt;&lt;em&gt;These amounts were lower than AAMI&lt;/em&gt; &lt;em&gt;and EPH standards. &lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; &lt;em&gt;Reverse osmosis systems could improve the quality of water used for hemodialysis. Based on the results of this study, it can be concluded that ahh the measured parameters in the hospitals werw below the standard levels. , indicating that removal efficiency reverse osmosis system parameters is desirable.&lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Keywords :&lt;/strong&gt;&lt;em&gt;hemodialysis centers, reverse osmosis, bojnurd &lt;/em&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>اسمز معکوس, همودیالیز, تصفیه</keyword_fa>
	<keyword>hemodialysis centers, reverse osmosis, bojnurd </keyword>
	<start_page>7</start_page>
	<end_page>16</end_page>
	<web_url>http://journal.nkums.ac.ir/browse.php?a_code=A-10-25-527&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>S.N</first_name>
	<middle_name></middle_name>
	<last_name>Asadzadeh </last_name>
	<suffix></suffix>
	<first_name_fa>سیده نسترن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسدزاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>asadzade-69@yahoo.com</email>
	<code>10031947532846005045</code>
	<orcid>10031947532846005045</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی خراسان شمالی</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name> langarizadeh </last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لنگری زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846005046</code>
	<orcid>10031947532846005046</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی خراسان شمالی</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Alizadeh </last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیزاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846005047</code>
	<orcid>10031947532846005047</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی  زاهدان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
